Antibody Selection Guide for IF

Choosing the right antibodies is crucial for successful immunofluorescence experiments. This guide helps you select and validate antibodies for your IF applications.

Primary Antibody Selection

Key Factors to Consider

1

Application Validation

  • Check if antibody is validated for immunofluorescence (IF)
  • Look for IF-specific datasheets or validation data
  • Antibodies validated for Western blot may not work in IF
  • Check manufacturer's recommended applications
2

Species Reactivity

  • Verify antibody recognizes your target species
  • Some antibodies are species-specific
  • Others cross-react with multiple species
  • Check datasheet for species reactivity information
3

Antibody Type

  • Monoclonal: More specific, consistent batches
  • Polyclonal: Higher sensitivity, may have more background
  • Choose based on your needs and availability
4

Fixation Compatibility

  • Some antibodies work with PFA fixation
  • Others require methanol or acetone
  • Some work with multiple fixatives
  • Check datasheet for fixation recommendations

Antibody Validation

Always Validate

Even if an antibody is "validated for IF," always validate in your specific system:

  • Your cell type or tissue
  • Your fixation conditions
  • Your experimental conditions
1

Positive Controls

  • Use known positive samples
  • Compare with published data
  • Verify expected localization
2

Negative Controls

  • Knockout or knockdown samples
  • Isotype-matched control antibodies
  • No primary antibody control

Secondary Antibody Selection

Key Factors

1

Species Matching

  • Secondary must match primary antibody species
  • Example: Mouse primary → anti-mouse secondary
  • Check species carefully before purchasing
2

Fluorophore Selection

  • Choose based on your microscope's filter sets
  • Consider brightness and photostability
  • For multi-color: ensure minimal spectral overlap
  • Common choices: Alexa Fluor, FITC, TRITC, Cy3, Cy5
3

Pre-adsorbed Antibodies

  • Reduces cross-reactivity
  • Important for multi-color experiments
  • May reduce background
  • Worth the extra cost for critical experiments
4

Concentration

  • Typically used at 1:200 to 1:1000
  • Start with manufacturer's recommendation
  • Titrate to find optimal concentration
  • Higher concentration can increase background

Antibody Storage and Handling

Critical

  • Store antibodies according to manufacturer's instructions
  • Avoid repeated freeze-thaw cycles
  • Aliquot antibodies if needed
  • Protect from light (especially secondary antibodies)
1

Storage

  • Most antibodies: -20°C or -80°C
  • Some: 4°C (check datasheet)
  • Use proper storage buffer
  • Avoid contamination
2

Handling

  • Thaw slowly on ice
  • Mix gently (no vortexing)
  • Use sterile techniques
  • Protect from light

Troubleshooting Antibody Issues

1

Weak Signal

  • Increase antibody concentration
  • Extend incubation time
  • Check antigen retrieval (for tissues)
  • Verify antibody is not expired
2

High Background

  • Reduce antibody concentration
  • Improve blocking
  • Use pre-adsorbed secondary
  • Check for cross-reactivity
3

Non-Specific Staining

  • Use proper controls
  • Verify antibody specificity
  • Check for cross-reactivity
  • Try different antibody